Cooling Towers 101: What Every Project Engineer Needs To Know

Cooling Towers 101: What Every Project Engineer Needs To Know

Have you been tasked with scoping and pricing a new cooling tower? If it’s your first time taking on a big task like this, it can be intimidating. Mistakes on projects like these can be easy to make  and result in significant unplanned costs.

If you are looking for more details, kindly visit Tengxiao Environmental Protection Equipment.

When faced with those realities, a lot of project engineers simply let their vendor or contractor size and scope the tower without getting too involved in the design and decisions. That’s where trouble can start because systems like these are unique, just like the jobs they’re designed to do. One size does not fit all. What works for one process on a summer day in Minnesota may not work for another on the hottest day in Nebraska.

That’s why starting with a good base of knowledge is critical. And why we’ve put together this quick nut-and-bolts cooling tower primer.


The Purpose Of A Cooling Tower

Almost every processing facility needs cooling. If steam is coming in, or doing any kind of heating, you have to take the BTUs out at some point. A cooling tower is, in essence, a heat exchanger. It rejects waste heat to the atmosphere by using air and water in direct or indirect contact to remove process heat and bring a water stream down to a lower temperature.

Wet Type vs Dry Type vs Hybrid Cooling Towers

There are a variety of cooling towers types, and they can vary in size from small roof-top units to large stand-alone hyperboloid structures that can be hundreds of feet tall. They’re named for the cooling method they employ: wet type, dry type and hybrid type.

  • Wet type cooling towers are the most common. As the names suggest, they allow a small portion of the water being cooled to evaporate into a moving air stream to provide significant cooling to the rest of that water stream. For obvious reasons, these are known as “evaporative” systems, and the heat from the water stream transferred to the air stream is then discharged to the atmosphere. Because the cooling potential of a wet surface is much better than a dry one, wet type systems are commonly used for processes that require significantly lower water temperatures.
  • Dry type cooling towers are what are known as indirect contact towers. In them the water is pumped through plates a heat exchanger coil and cooled with air. You don’t get the evaporative cooling affect a wet type tower provides, but if you don’t need to get the water temperature down below, say, 100 degrees Fahrenheit, a dry type tower can be very effective, and more energy efficient in very humid environments. A good example of a dry type cooling system is the radiator in your vehicle.
  • A hybrid type system uses a combination of direct and indirect cooling for heat rejection. In some cases, it can be a combination of an indirect cooling exchanger with outside water spray. In others it can be a wet type tower used to cool the refrigerant loop for a large chiller systems. In either case, it combines the methodologies of both wet and dry types to achieve the required cooling.  Applications include heavily urbanized areas where the vapor plume is undesirable or arid environments where only a small amount of evaporative cooling is needed to reach the cold water temperature.

Speaking of chillers, they’re an alternative or complementary cooling option. They use a refrigerant fluid to supplement cooling, and they may be the right application for some processes and locations. They’re more expensive to operate, but for companies with unique or seasonal needs (in the summer, for example, when you have higher humidity and need a supplemental system to get water temperatures down an extra five degrees), they can make a sensible option.  

Choosing the right cooling tower type for your operation really depends on what you’re trying to cool and the temperature you need to get it down to. The best advice is to know your product and your process, and choose the option that gives you the most precise, efficient, cost-effective cooling.

Cooling Tower Design: The Biggest Decisions

Now that we’ve covered the different types of cooling towers, let’s dig into some of the things you’ll want to think about when designing yours. And size and location are the key factors.

Tower Location:  You need to decide where it’s going to sit. Rooftops are an option if you’re pressed for space, but some towers can be pretty sizable and need to stand on their own. They also need very good airflow, which means putting them next to another building can be problematic. Keeping them free of compromising debris can be tough, too, so placing them near load-outs and emission sources may be a bad choice. There may not be a perfect location, but one that minimizes these issues will be better.

Water Pump Location: This can be a bit of a double-edged sword. It’s best not to locate the tower too close to building, but close enough to put the pumps inside so that it they won’t freeze in the winter.  For remote tower locations, a removable, heat-traced box or a small heated building may be necessary.

Pipe Sizing: The location of the water pump partially determines your pipe sizing, which is another important design factor. Locating the pump away from the building demands longer suction piping. But if you size the pipe right (i.e., bigger), you should have no problem going farther away. You also want your pipes big enough to prevent pump cavitation issues. Unfortunately, because manufacturers want to keep their prices competitive, they tend to spec the smallest size pipes they can. So be sure to specify the pipe and nozzle sizes you actually need.

Header Sizing: Another piping-related consideration is the header size for utility piping out to the plant. Going with a bigger bore pipe will generally allow you to have longer runs, keep velocities down and prevent bottlenecks. You may not know those measurements in advance, but a bigger pipe is probably better.

Water Pump Sizing: Sizing the tower water pump can be a challenge, too. Keep in mind that you need the pump to develop enough pressure to get water to the highest and farthest places in the plant. If you don’t size the pressure drop right, it won’t get there. Pumps are typically sized for 65 feet of head. In our experience, though, 90 feet of head is what you really need to make sure your pump can do that job. But you need to know for sure.

Determining the design pump flow is not always straightforward, either.  There could be intermittent users, seasonal users, and small users where you don’t know the load, such as hydraulic oil coolers.  Plants commonly operate over the design capacity, which means the cooling tower needs to keep up. It is important to have some excess flow in the pump and tower design for these situations.

Basic Cooling Tower Equipment

Determining a cooling tower type and understanding some of the key design considerations will get you headed in the right direction. But they won’t keep your tower up and running. That will depend on reliable components and preventive maintenance.

There are structural components, which include:

  • The Cold-Water Basin
  • Tower Framework
  • Water Distribution System
  • Fan Deck
  • Fan Cylinders
  • Fill
  • Drift Eliminators
  • Casing
  • Louvers
  • Access And Safety Components

There are mechanical components, which include:

For more how to design cooling towerinformation, please contact us. We will provide professional answers.

  • Fans
  • Drive shafts
  • Float Valve

There are electrical components, which include:

  • Motors
  • Motor controls
  • Variable Frequency Drives
  • Wiring systems
  • Control instruments
  • Basin Heater

Each of the items above need to be thoughtfully spec’d and budgeted for—as well as planned for maintenance and repair activities.  It is important to understand what a supplier has included in their price and what you will need to furnish in addition.

If you’re designing a complete system, you’ll need plenty of ancillary equipment and components as well. These items may include:

  • A supporting structure (i.e., pad, legs)
  • Access walkways / ladders
  • Piping
  • Utilities
  • Tower Water Pump

As you can see, a cooling system is more than just a tower. It’s a complex network of parts and systems and processes. Making sure yours does the job you need it to do depends on keeping all those parts in mind at the beginning so they don’t let you down in the end.

Common Cooling Tower Oversights

Even if you design and prepare diligently, issues can arise. Anticipating some of them can allow you to plan better at the outset and make dealing with any that come up a little less stressful.

  • Tower Sizing: The biggest challenge deals with sizing. And that’s especially true in areas where the conditions change over the course of the year. If you size your cooling tower for an average condition, it may not get the job done in the peak of summer or the dead of winter. Air temperature and humidity impact wet type towers the most. They need to pull sufficient airflow in any condition, and you need to be sure you have enough surface area to do that. Sizing your tower right for the extremes from the beginning is the best way to avoid this issue.
  • Pipe Sizing: We mentioned pipe sizing earlier in the design section, but it bears repeating. When pump suction piping isn’t sized properly (they’re usually too small), you run into issues. Size it right for the process and pump location and you’ll save yourself a potential headache.
  • Add-Ons: Expansion can be another pitfall. If you design your cooling tower for a set capacity, then increase the load over time with add-on projects, it’s not going to cool the way it should. If you’re scoping from scratch, consider what other processes may need to feed into the tower in future. Then make some adjustments in the design phase (e.g., motor size, blade pitch) that can increase your cooling capacity without requiring a new tower structure down the line.
  • Fouling: When cooling towers suck in air, that’s not the only thing they suck it. Dust, dirt, leaves, seeds and anything else that’s flying by can get sucked in, too. That makes fouling another common problem. Making sure you include a strainer basket in your scope can limit the rather dirty work of cleaning the tower out. And take it from our engineers who’ve seen what can wind up in there, it’s a task you don’t want.

Proper planning early in the scoping phase can help to forecast and prevent many of these issues. Bringing an experienced engineer to the table early is a wise investment.

The Importance of Getting Good Advice

Cooling Tower Factors: Temperature, Range & Approach | FCS

When asked, most operators will provide the purpose of a cooling tower: to reduce the temperature of water to the lowest practicable point.  Pressed on the topic, however, most could not explain how the ambient temperatures and humidity affect the performance of the tower.  If the temperature was 70°F outside, the average operator might tell you that they would expect their CT to put out 70°F water.  But is this always true?  Is the tower operating efficiently?

Two important (and often misunderstood) factors that describe cooling tower performance are range and approach.  To understand these terms, one must understand the difference between “dry bulb temperature” and “wet bulb temperature.”

Temperature

Ask a friend to define temperature and you will likely hear something along the lines of “how hot or cold something is;” and this definition is good enough to get most of us through the day.  Regarding ambient temperature, most people perceive it to be what the thermometer reads or what the television weatherperson tells us.  But the television weatherperson always throws in ambiguous qualifiers: humidity, heat index, dew point.  These terms play an important part not only in how it feels outside but in how well cooling towers perform.

While that thermometer on the front porch does a good job of telling you one thing: dry bulb temperature, it doesn’t tell you how comfortable that temperature is right now.  And, we have all heard the people in Phoenix say, “sure it’s 110°F, but it’s a dry heat.”  After you roll your eyes and stop and think about it – what does that mean?

A typical outdoor thermometer is showing you what is referred to as the “dry bulb temperature.”  It does not take into account the relative humidity in the air.  Relative humidity is an expression of how much moisture is actually in the air compared to how much there could be at this temperature.  If the humidity is 100%, the air is completely saturated with water and no evaporation is possible.  This means that neither your facility’s cooling tower nor your body perspiring will enjoy the effects of evaporative cooling.  You will just sit there and sweat and your cooling tower will underperform one located in lower humidity at the same temperature.

To measure the effects of both the temperature and humidity together, we use a psychometric chart.  These charts combine the effects of humidity and temperature to calculate the “wet bulb temperature.”  The wet bulb temperature describes the effects of evaporative cooling on both your body and on cooling towers.  Using these charts, it is easy to see how a 95°F/30% humidity day in Phoenix can feel downright comfortable, while the 80°F/70% day in Atlanta is uncomfortable – you just don’t get the same evaporative cooling effect in Atlanta.  This is why most facilities measure ambient temperature and humidity.

Approach

Cooling tower approach is the difference in temperature of the water entering the basin (cold) and the wet bulb temperature.  For the purpose of tower design, a tower with a smaller approach (small delta between basin water temperature and wet bulb temperature) is considered superior.  Modern towers commonly have approach temperatures as low as 5°F.  While it is possible to have a smaller approach, it becomes cost-prohibitive since the size of the tower grows exponentially as approach lowers, which in turn requires more pumps and fans.  This leads to more auxiliary power usage and diminishing returns.

In a mechanical draft tower, the only variables that change approach are wet bulb temperature and heat load (the amount of heat removed by the tower).  If your facility has variable speed cooling tower fans, approach can be reduced by increasing fan speed and therefore taking advantage of more evaporative cooling.  If fan speed and heat load are maintained constant for a given wet bulb temperature, approach is constant.

Range

Put simply, range is the difference between the temperature of water entering the cooling tower and leaving the cooling tower.  It is determined by the heat load on the tower and the water circulation rate.  If pump speed is constant and heat loads are constant, the tower range does not change.  This means that for a clean, properly functioning tower, wet bulb temperature does not affect cooling tower range.  Consequently, in practice, for a given water flowrate and heat load, if wet bulb temperature increases, tower inlet and outlet temperature increase proportionally.  The result is an unchanged range.

Typically, cooling towers are designed to cool a specified maximum flowrate of water from one temperature to another at an exact wet bulb temperature.  For example, a designed tower may be guaranteed to cool 10,000 gpm of water from 95°F to 80°F at 75°F wet bulb temperature.  In this case, the range is 15°F and the approach is 5°F.  These design calculations are always done using average wet bulb temperatures at the site where the tower will be installed to ensure performance guarantees are met.

Summary

With an understanding of wet bulb temperature, range and approach, the operator should be able to understand the lowest theoretical basin temperature for the current temperature and humidity.  Using the cooling tower range, they can estimate how efficiently the process is functioning in comparison to cooling tower design.  Armed with their newfound knowledge of these properties, the operator can efficiently stage pumps and fans without trying to squeeze out one more degree of approach that is simply not physically possible.

Contact us to discuss your requirements of crossflow vs counterflow cooling towers. Our experienced sales team can help you identify the options that best suit your needs.